Message us on WhatsApp
Insulated rectangular ductwork installed by Cavalli Ventilation, run off an air handling unit and carried level along the roof of a commercial unit

Family-run · South East London · Since 2019

Ventilation that actually shifts the damp

Ductwork, MVHR, extract systems and air conditioning — designed, installed and commissioned across Beckenham, Bromley, West Wickham, Chislehurst, Dulwich and South East London.

  • 20+ yearson the tools
  • CPD certificatedBESA Academy & CIBSE-approved
  • Commissionedairflow measured, not assumed

Start with what you can actually see

Most people arrive here with a symptom rather than a diagnosis, and the symptom is usually enough to narrow it down. Each of these explains what is happening and what genuinely fixes it — no form, no email address, just the answer.

What We Do

Domestic and commercial ventilation, heating and cooling — designed properly, installed neatly, and commissioned so the airflow is measured rather than assumed.

Heat recovery, in section

Where the warmth goes

An extract fan throws your heating out through the wall. A heat recovery unit takes the warmth out of the stale air on its way past and hands it to the fresh air coming in. Scroll to follow one lungful of air all the way through the machine.

OUTSIDE INSIDE — CEILING VOID BEDROOM BATHROOM HEAT RECOVERY UNIT Condensate drain, trapped RECOVERED 19° ~90% 21°C from kitchen & bathroom 5°C leaves cold 3°C outdoor air 19°C delivered to the bedrooms WHAT IS INSIDE 1 Filter on each incoming stream 2 Counter-flow heat exchanger 3 One fan each way, balanced 4 Insulated — outdoor runs only 1 2 3 4 Heat crosses. The air does not.
  • Insulated — outdoor runs only
  • Filter on each incoming stream
  • Counter-flow exchanger

Illustrative figures for a good counterflow unit — about 90% heat recovery — on a 3 °C day. Manufacturers quote up to roughly 90% for this type; the real numbers depend on the unit and the duct layout, and are proved by measurement at commissioning, not by the brochure. The efficiency also depends on the filters being changed: a loaded set drops the airflow and takes the recovery down with it.

  1. 1

    Extract · 21 °C

    The damp air leaves first

    A valve in the bathroom ceiling pulls air out continuously — from the rooms where the moisture is actually made. It leaves at room temperature, taking the moisture with it before it reaches a cold wall and turns into condensation.

  2. 2

    Exhaust · 5 °C

    It gives up its warmth on the way out

    Through a filter, through one half of the exchanger, through the fan and out to the wall grille. By the time it reaches the outside it is close to outdoor temperature — the warmth you paid for has been left behind in the unit.

  3. 3

    Intake · 3 °C

    Cold fresh air comes in the other side

    Filtered outdoor air enters through its own grille, set well away from the exhaust so the unit can't breathe back in what it has just thrown out, and runs into the other half of the exchanger. The plates keep the two streams apart: heat passes between them, air never does.

  4. 4

    Supply · 19 °C

    It arrives warm, where you sleep and sit

    The warmed fresh air is delivered to the bedrooms and living room. That is the whole trick: the full air change the regulations ask for, without paying to heat the house twice — which is exactly what an extract fan on its own makes you do.

About us

You deal with the person who surveyed it

Cavalli Ventilation is a family-run business in South East London. Niki has worked in ventilation since 2003 and has traded as Cavalli Ventilation since July 2019. His father works alongside him, and his son joins them when they are busy. The person who comes out and looks at your property is the person who does the work.

We are ventilation engineers first. We design, install and commission MVHR, MEV, PIV, extract systems, air handling units, ductwork, duct socks and air conditioning, across both commercial and residential work. That is the reason our damp surveys measure the ventilation rather than just recommending you improve it — it is the system we install for a living, and we can prove what it achieves before and after.

We do not do bodge jobs. Every install is left as though it were going in our own home — set out properly, finished properly, commissioned to a measured rate and documented. If it does not look right, it is not finished.
  • 2003 In ventilation since
  • July 2019 Trading as Cavalli Ventilation
  • Family-run Three generations on the tools
  • Measured Airflow recorded at every terminal, not assumed
  • Commercial & domestic Warehouses and gyms through to a single bathroom fan
  • Company no. 12092552 Registered in England & Wales

Recent work

Bare soffit to a commissioned system

Drag the handle across the photograph. This one is LT Foods in Harlow: air handling units, insulated supply ducting run the length of the space, and grilles set out to give even distribution across the floor — then balanced and measured before we called it finished.

Photographs of recent installations are on our Instagram while we put this gallery together.

See our work on Instagram
Heating & cooling ductwork

Family-run since 2019, and still the people who turn up

You deal with the same engineers from survey to commissioning. No call centre, no subcontracted crew you have never met, and no job signed off without the airflow measured. And you follow the whole job in our own client app — quotes, documents, servicing dates and a direct line to your engineer.

20+ Years on the tools
36 South East London areas covered
CPD certificated
  • Ventilation: Approved Document FNuaire, through the BESA Academy
  • Understanding Mechanical VentilationCIBSE-approved CPD · Airflow, through the BESA Academy

Both held by this business — the certificates are published on the site.

Commissioned, not guessed

Every install is signed off with a calibrated anemometer at the grille. A fan rated at 30 l/s routinely delivers far less once ducting, bends and a terminal are on it — the only number that counts is the one measured in your room.

Two things you can try right now

Both are free, take a minute, and tell you something useful before you speak to anyone.

Not sure where to start?

Send us a message with what you have noticed at home. We will tell you honestly whether you need a survey, a system, or neither.

Or see what it costs — unlike most in this trade, we publish our prices.

Trained on the systems we install

Certificated — and here they are

Most trade sites show you a row of logos. These are the actual certificates, held by this business. Tap either one to read it, or download the PDF.

  • 12-month workmanship guarantee On top of the manufacturer’s warranty, which we register in your name. If anything we installed fails because of the way we installed it, we come back and put it right. What it covers.
  • Company no. 12092552 Registered in England & Wales. Trading as Cavalli Ventilation since July 2019, and in ventilation since 2003.
  • Airflow measured on every install A calibrated anemometer at the grille, recorded and handed over. The only figure that counts is the one measured in your room.