Domestic and commercial work across South East London — with the airflow measured at the grille, not assumed from the box.

Heat recovery care plans

Installed once. Measured every year after.

Ventilation is the one thing in a house that stops working without ever breaking. A care plan is a booked visit every year: filters, a full clean, and every valve measured with the figure written down next to last year’s — so you know it is still doing the job it was put in to do.

Flat£199a year
House£265a year
Large house£325a year
  • Or £18 – £28 a month, filters included
  • We pick the month, you get the lower price
  • Plans for PIV, extract and air conditioning are quoted

Domestic and commercial ventilation, heating and cooling — designed properly, installed neatly, and commissioned so the airflow is measured rather than assumed.

A Nuaire MRXBOX heat recovery unit suspended in a ceiling void between timber joists, with insulated ducting run over the top of it
MRXBOX heat recovery unit, suspended in the ceiling void.
  1. 1 Ceiling joists
  2. 2 Heat recovery unit
  3. 3 Insulated duct

Heat recovery

Fresh air without paying to heat it twice

An MVHR unit extracts damp air from your wet rooms and supplies filtered fresh air to the bedrooms and living space, passing the two streams either side of a heat exchanger so most of the warmth stays in the house.

It only works if the ducting is right. Insulated where it runs cold, kept as short and straight as the building allows, and balanced room by room at commissioning — otherwise you have an expensive box moving the wrong amount of air.

See how it works in your home

Heat recovery, in section

Where the warmth goes

An extract fan throws your heating out through the wall. A heat recovery unit takes the warmth out of the stale air on its way past and hands it to the fresh air coming in. Scroll to follow one lungful of air all the way through the machine.

OUTSIDE INSIDE — CEILING VOID BEDROOM BATHROOM HEAT RECOVERY UNIT Condensate drain, trapped RECOVERED 3° → 19° ~90% 21°C from kitchen & bathroom 5°C leaves cold 3°C outdoor air 19°C delivered to the bedrooms WHAT IS INSIDE 1 Filter on each incoming stream 2 Counter-flow heat exchanger 3 One fan each way, balanced 4 Insulated — outdoor runs only 1 2 3 4 Heat crosses. The air does not.
  • Insulated — outdoor runs only
  • Filter on each incoming stream
  • Counter-flow exchanger

Illustrative figures for a good counterflow unit — about 90% heat recovery — on a 3 °C day. Manufacturers quote up to roughly 90% for this type; the real numbers depend on the unit and the duct layout, and are proved by measurement at commissioning, not by the brochure. The efficiency also depends on the filters being changed: a loaded set drops the airflow and takes the recovery down with it.

  1. 1

    Extract · 21 °C

    The damp air leaves first

    A valve in the bathroom ceiling pulls air out continuously — from the rooms where the moisture is actually made. It leaves at room temperature, taking the moisture with it before it reaches a cold wall and turns into condensation.

  2. 2

    Exhaust · 5 °C

    It gives up its warmth on the way out

    Through a filter, through one half of the exchanger, through the fan and out to the wall grille. By the time it reaches the outside it is close to outdoor temperature — the warmth you paid for has been left behind in the unit.

  3. 3

    Intake · 3 °C

    Cold fresh air comes in the other side

    Filtered outdoor air enters through its own grille, set well away from the exhaust so the unit can't breathe back in what it has just thrown out, and runs into the other half of the exchanger. The plates keep the two streams apart: heat passes between them, air never does.

  4. 4

    Supply · 19 °C

    It arrives warm, where you sleep and sit

    The warmed fresh air is delivered to the bedrooms and living room. That is the whole trick: the full air change the regulations ask for, without paying to heat the house twice — which is exactly what an extract fan on its own makes you do.

Landlords, letting agents & managing agents

Damp in a let property is a different job

Not because the physics changes — it does not — but because you need the paperwork as much as the fix. A survey that says which of the three damps it actually is, the work that meets Part F, and commissioning figures in writing, so the file stands up if a tenant, a council or an insurer ever asks.

  • It is almost always the landlord’s duty, and not because of Awaab’s Law — that is social housing and is not in force for the private rented sector. What applies to you today is the Fitness for Human Habitation Act 2018, which a tenant can act on themselves.
  • “The tenant dries washing indoors” is not a defence. A household of four puts 10–15 litres of water a day into a home. The question is whether the property can deal with it.
  • Portfolios are surveyed as a batch, reported in one comparable format, and scheduled around tenancies rather than around us.
Damp and mould for landlords and agents
Servicing and maintenance

A system that met the figure on handover is not still meeting it

Ventilation is the only thing in a house that quietly stops working without ever breaking. Nothing trips, nothing leaks, nothing makes a noise — the filters load up, the airflow halves, and the first anyone knows is a black line round the bathroom ceiling two winters later.

So we do not sell a callout. We sell a visit that ends in a measured figure, the same way the installation did.

MVHR

Filters to the manufacturer’s interval, heat exchanger drawn and cleaned, condensate trap checked, and the unit re-balanced — then every valve re-measured and the figures written down.

A loaded filter set can take a third off the airflow before anyone notices. Re-measuring is the only way to know it is still doing what it was commissioned to do.

Extract fans and MEV

Performance tested at the grille with a calibrated anemometer against the Approved Document F rate for that room, cleaned, and re-commissioned. If it cannot make the figure, you get told why.

Most of the fans we test in older properties do not hit their rate. A test is what turns “there is a fan in there” into something you can act on.

PIV

Filter changed, airflow checked at the diffuser, heater and controls tested, and the loft conditions round the unit looked at while we are up there.

A PIV pushing through a blocked filter is a fan heating a loft. They are cheap to service and almost never are.

Air conditioning

Filters, coils, condensate and drainage, electrical connections and a performance check before the hot weather finds the fault for you.

Refrigerant circuit work — recovery, charging and leak testing — is carried out under F-Gas certification by our refrigerant partner, because it is illegal to do otherwise. The work listed above needs no F-Gas certificate and we do it ourselves.

For a managed portfolio

One visit per property per year, planned round the summer rather than squeezed into the winter when everything else is going wrong. Each one ends with a dated certificate carrying the measured figures, filed against that property in your account.

That is the record that answers a complaint before it becomes a claim: not “it was serviced”, but what it was achieving, on what date, against what standard.

Ask about a service plan
  • Scheduled, not chased. We come to you with the year’s list, you say yes.
  • One certificate per property. Measured figures, dated, downloadable.
  • Flagged before it fails. Anything heading for a problem gets quoted, not hidden.
  • Access sorted with the tenant. Booked directly, so you are not the middleman.
For builders, loft converters and developers

First fix to your programme, and the paperwork for sign-off

You do not need the ventilation lecture. You need the ductwork in between the joists before the boards go on, on the day you said, and the numbers for building control at the end of it.

  • First fix to programme. Ducted in the void, supported properly and pressure-sound before it disappears.
  • Designed to Part F, not guessed. Rates worked out for the finished layout, including the rooms you are adding.
  • Commissioning certificate for the pack. Measured at every valve, which is what building control asks for and what most jobs cannot produce.
  • Loft conversions especially. Turning a cold loft into a bedroom moves the dew point and changes the whole house’s ventilation. It is the single commonest way a house that was fine develops a mould problem.
Talk to us about a programme

First fix

The work that decides whether it ever performs

Ventilation is won or lost before the ceiling goes on. Once plasterboard is up, the duct route is fixed, and a run forced around a joist it was never planned for will cost you airflow for the life of the building.

We set out first fix against the drawings and the other trades — joist positions, service voids, where the pipework and cabling are already going — so the ducting takes the shortest sensible route rather than the last gap left over.

Talk to us before first fix
Ceiling void at first fix, with joists, heating flow and return pipework and insulated ducting set out before boarding
Ceiling void at first fix, before boarding.
  1. 1 Joists set out
  2. 2 Heating flow and return already run
  3. 3 Duct route kept clear

Not sure where to start?

Send us a message with what you have noticed at home. We will tell you honestly whether you need a survey, a system, or neither.

Or see what it costs — unlike most in this trade, we publish our prices.

Trained on the systems we install

Certificated — and here they are

Most trade sites show you a row of logos. These are the actual certificates, held by this business. Tap either one to read it, or download the PDF.

  • 12-month workmanship guarantee On top of the manufacturer’s warranty, which we register in your name. If anything we installed fails because of the way we installed it, we come back and put it right. What it covers.
  • Company no. 12092552 Registered in England & Wales. Trading as Cavalli Ventilation since July 2019, and in ventilation since 2003.
  • Airflow measured on every install A calibrated anemometer at the grille, recorded and handed over. The only figure that counts is the one measured in your room.